Description

Features

  • ON LINE, SINUSOIDAL, DOUBLE CONVERSION
  • FULL IGBT DESIGN ALLOWING HIGHER SWITCHING FREQUENCIES AND SUBSEQUENT HIGHER EFFICIENCY AND RELLIABILITY
  • MICROPROCESSOR CONTROLLED
  • "BATTERY HEALTH GUARD" SYSTEM IMPROVING THE LIFE TIME OF THE BATTERY THROUGH : programmable discharge test-temperature compensation charging-end discharge voltage adaptable to load-overvoltage protection-minimal ripple current
  • PROVIDING THE HIGHEST EFFICIENCY VALUES AMONG UNITS OF THE SAME RATINGS up to 99% in Eco-mode
  • NEW VENTILATION SYSTEM
  • PARALLELABLE UP TO 8 UNITS
  • BUILT IN PROTECTION WITH MANUAL BY-PASS
  • LARGE NUMBER OF COMMUNICATION POSSIBILITY : RS232 electrical and optical-siel Monitoring Software-OCS3-SNMP compatible-connectable with Teleglobal Service, the remote tele diagnosis system
  • WIDE LIST OF OPTIONS AVAILABLE WHICH CAN ALSO BE FITTED INTERNALLY, SUCH AS : 12 Pulse Configuration-isolation transformer-back feed protection device-battery isolation fault detector-earth fault detector-THD harmonic filter
  • COMPLIANCE WITH THE FELEVANT INTERATIONAL STANDARDS CERTIFIED BY "CESI CERT. EMC"MARK
  • OUTPUT POWER(P.F. 0,8): 20-30-40-50-60-80-100-120-150 kVA
  • NOMINAL INPUT VOLTAGE VAC 400/-15+10%
  • NOMINAL OUPUT VOLTAGE VAC 400±1% 50-60 Hz
  • OUTPUT VAVE FORM SINUSOIDAL
  • SWITCHING TIME ZERO
  • DIMENSIONS(W x D x H)mm. 700 x 850 x 1400 / 1100 x 800 x 1400
  • WEIGHT : Kg 300-600
  • FLEXIPOWER : technical data

FLEXIPOWER'S UNIQUE FEATURES

Flexipower has been designed to house a broad spectrum of devices which are of paramount importance th lthe user WITHOUT THE NEED FOR ANY STRUCTURAL CHANGES EVEN AFTER INSTALLATION.
The machine features a dedicated section that can be fitted with:

  • RFI filters built to EN 50091-2 standards as well as to more stringent staandards for protection from radiofrequency disturbances.
  • P.F.correction to a uwable.9 where no central P.F.correction circuit is available.
  • LF harmonic reduction input of less than 10% by means of a dedicated device.
  • UPS electroinsulation transformes.

FLEXIPOWER'S MAIN FEATURES

  • FLEXIPOWER is a continuously operation dual conversion UPS complying with IEC 146-4 and EN 50091-3 European Stadards.
  • - Sophisticated HF IGBT technology for high levles of efficiency and ultra-low noise levels ina compact unit.
  • On-line SINEWAVE and ZERO clamping time.
  • Disconnecting switches built into the UPS.
    A standard Flexipower is fitted with the following disconnecting switches:
    Fused rectifier disconnecting switch.
    Output disconnecting switch:disconnects the UPS fully from the load.
    Fused reserve line disconnecting switch:disconnects the reserve line from the static switch and protects the statices switch semiconductors.
    Manual by-pass disconnecting switch:runs the load directly from the line power and cuts off the UPS.
  • 93% efficiency for>50% load and 90% efficency for>30% load.
  • IP21 degree of protection even with open door.
  • Air cooling with air intake from above to minimise the build-up of dust.
  • Power return and insulation control relay wigh local trip signal plus remote trip signal using a RS232 port.
  • Dddicated remote-control switch disconnects the static switch from the reserve line for maximum protection if the power return relay trips.
  • Output relay with switching contacts whose functions can be modified by firmware.
  • if being used with a power generator,the power absorbed by the rectifier can be limited to
    prevent the power generator from overloading.

CONTROL AND MONITORING PANEL

Located on the front of the UPS and consisting of the following two components:

  • 80-character LCD and control keys
  • LED operating overview providing an instant picture of the operating status of the various UPS sections.
    The main functions are:
  • Cyclic view every 4 secs of the operating status of the various UPS sections.
  • Piloted view of the UPS operating status as required by the operator by means of the control keys.
  • Voltage,current,frequency and battery backup time values displayed in real time.
  • Alarm listing complete with even time and date and scrolling facility.
  • Battery efficiency test:may be programmed at intervals as specified by the operator.
  • Information displayed on the monitor ina choice of three languages.
  • Communicated with the main contrl/monitoring software programmers.
  • Battery recharged according to environmental temperature.

INTERFACE FOR RS232 AND FIBER OPTIC CONNECTIONS

  • This interface in always provided in the UPS and may be customised using the various versions available. The main ones are:
  • Monitoring of the UPS by a PC installed with a software programme for switching off the system,signalling and alarms.
  • Communicating with specialised software programmes installed in computers with a serial EIA-RS232 interface to activate all SIEL software,called OCSystems,may also be used;this programme gives full and total control of all UPS functions and records an exhaustive event history.
  • Remote UPS signaliing systems with special reference to EPO control that isolates and switches off the UPS fully in the event of an emergency.
  • Remote handling and diagnostics.


Product Image

  • Flexi Power image

Other products from this supplier

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Hyunmoon Lee
Daesung Engineering
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Other Electrical Equipment
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838