Features
- ON LINE, SINUSOIDAL, DOUBLE CONVERSION
- FULL IGBT DESIGN ALLOWING HIGHER SWITCHING FREQUENCIES AND SUBSEQUENT HIGHER
EFFICIENCY AND RELLIABILITY
- MICROPROCESSOR CONTROLLED
- "BATTERY HEALTH GUARD" SYSTEM IMPROVING THE LIFE TIME OF THE BATTERY
THROUGH : programmable discharge test-temperature compensation charging-end
discharge voltage adaptable to load-overvoltage protection-minimal ripple
current
- PROVIDING THE HIGHEST EFFICIENCY VALUES AMONG UNITS OF THE SAME RATINGS
up to 99% in Eco-mode
- NEW VENTILATION SYSTEM
- PARALLELABLE UP TO 8 UNITS
- BUILT IN PROTECTION WITH MANUAL BY-PASS
- LARGE NUMBER OF COMMUNICATION POSSIBILITY : RS232 electrical and optical-siel
Monitoring Software-OCS3-SNMP compatible-connectable with Teleglobal Service,
the remote tele diagnosis system
- WIDE LIST OF OPTIONS AVAILABLE WHICH CAN ALSO BE FITTED INTERNALLY, SUCH
AS : 12 Pulse Configuration-isolation transformer-back feed protection device-battery
isolation fault detector-earth fault detector-THD harmonic filter
- COMPLIANCE WITH THE FELEVANT INTERATIONAL STANDARDS CERTIFIED BY "CESI
CERT. EMC"MARK
- OUTPUT POWER(P.F. 0,8): 20-30-40-50-60-80-100-120-150 kVA
- NOMINAL INPUT VOLTAGE VAC 400/-15+10%
- NOMINAL OUPUT VOLTAGE VAC 400±1% 50-60 Hz
- OUTPUT VAVE FORM SINUSOIDAL
- SWITCHING TIME ZERO
- DIMENSIONS(W x D x H)mm. 700 x 850 x 1400 / 1100 x 800 x 1400
- WEIGHT : Kg 300-600
- FLEXIPOWER : technical data
FLEXIPOWER'S UNIQUE FEATURES
Flexipower has been designed to house a broad spectrum of devices which are
of paramount importance th lthe user WITHOUT THE NEED FOR ANY STRUCTURAL CHANGES
EVEN AFTER INSTALLATION.
The machine features a dedicated section that can be fitted with:
- RFI filters built to EN 50091-2 standards as well as to more stringent
staandards for protection from radiofrequency disturbances.
- P.F.correction to a uwable.9 where no central P.F.correction circuit is
available.
- LF harmonic reduction input of less than 10% by means of a dedicated device.
- UPS electroinsulation transformes.
FLEXIPOWER'S MAIN FEATURES
- FLEXIPOWER is a continuously operation dual conversion UPS complying with
IEC 146-4 and EN 50091-3 European Stadards.
- - Sophisticated HF IGBT technology for high levles of efficiency and ultra-low
noise levels ina compact unit.
- On-line SINEWAVE and ZERO clamping time.
- Disconnecting switches built into the UPS.
A standard Flexipower is fitted with the following disconnecting switches:
Fused rectifier disconnecting switch.
Output disconnecting switch:disconnects the UPS fully from the load.
Fused reserve line disconnecting switch:disconnects the reserve line from
the static switch and protects the statices switch semiconductors.
Manual by-pass disconnecting switch:runs the load directly from the line power
and cuts off the UPS.
- 93% efficiency for>50% load and 90% efficency for>30% load.
- IP21 degree of protection even with open door.
- Air cooling with air intake from above to minimise the build-up of dust.
- Power return and insulation control relay wigh local trip signal plus remote
trip signal using a RS232 port.
- Dddicated remote-control switch disconnects the static switch from the
reserve line for maximum protection if the power return relay trips.
- Output relay with switching contacts whose functions can be modified by
firmware.
- if being used with a power generator,the power absorbed by the rectifier
can be limited to
prevent the power generator from overloading.
CONTROL AND MONITORING PANEL
Located on the front of the UPS and consisting of the following two components:
- 80-character LCD and control keys
- LED operating overview providing an instant picture of the operating status
of the various UPS sections.
The main functions are:
- Cyclic view every 4 secs of the operating status of the various UPS sections.
- Piloted view of the UPS operating status as required by the operator by
means of the control keys.
- Voltage,current,frequency and battery backup time values displayed in real
time.
- Alarm listing complete with even time and date and scrolling facility.
- Battery efficiency test:may be programmed at intervals as specified by
the operator.
- Information displayed on the monitor ina choice of three languages.
- Communicated with the main contrl/monitoring software programmers.
- Battery recharged according to environmental temperature.
INTERFACE FOR RS232 AND FIBER OPTIC CONNECTIONS
- This interface in always provided in the UPS and may be customised using
the various versions available. The main ones are:
- Monitoring of the UPS by a PC installed with a software programme for switching
off the system,signalling and alarms.
- Communicating with specialised software programmes installed in computers
with a serial EIA-RS232 interface to activate all SIEL software,called OCSystems,may
also be used;this programme gives full and total control of all UPS functions
and records an exhaustive event history.
- Remote UPS signaliing systems with special reference to EPO control that
isolates and switches off the UPS fully in the event of an emergency.
- Remote handling and diagnostics.